Your network needs a cable that meets fire code and still delivers 10 Gbps. BERK-TEK CAT6A plenum cables do both. This collection includes the RDT, LANmark-10G2, and LANmark-XTP designs in 1000 ft lengths, and every cable carries a CMP rating for air-handling spaces. You can pick the diameter, color, and design that fits your pathway, then order with tax-free delivery across the USA.
All three designs share one core build, and each adds its own strengths:
● Plenum-rated jacket: The CMP rating covers air-handling spaces, and ETL or UL listings back it.
● Solid bare copper: 23 AWG conductors in four unshielded twisted pairs suit permanent links to jacks and patch panels.
● 10G performance: Each cable supports 10GBASE-T up to 100 meters, plus 2.5G and 5G Ethernet.
● Extra bandwidth: The RDT and LANmark-10G2 are characterized to 750 MHz, which is 250 MHz above the Cat6A standard.
● Alien crosstalk margin: The RDT carries an ETL-verified 8 dB margin. Every LANmark-10G2 reel passes 2 dB NEXT and 4 dB ACRF margins before it ships.
● PoE support: The RDT supports PoE Types 1–4 and carries a 105°C listing.
● Slim profile: The RDT measures 0.230 in and has no cross filler.
● FEP insulation: The LANmark-10G2 and LANmark-XTP use FEP, a material chosen for low smoke and low flame spread.
● 1000 ft lengths: One reel covers long runs without splices.
Plenum spaces move air through a building. These include the areas above drop ceilings and below raised floors. A CMP jacket limits flame spread and smoke, so fire code calls for it in these spaces. You can also install CMP cable in riser and general-purpose areas, so one cable type covers the whole building. Check the jacket legend before you install: it shows the CMP mark and the ETL or UL listing.
Match the cable to your pathway, power load, and layout. Check these points before you order:
● Pathway space: Compare the outer diameter with your conduit or cable tray. A slimmer cable fits more runs in the same space.
● Cable density: Bundled cables raise alien crosstalk. Look for a stated alien crosstalk margin when you pull many runs together.
● PoE load: Power heats bundled cables. Check the temperature listing and PoE type before you connect access points or cameras.
● Run length: Keep each permanent link within 90 meters. That leaves 10 meters for patch cords inside the 100-meter Cat6A limit.
● Color coding: Assign one color to each network, such as data, wireless, or security. You trace and label runs faster.
Use them for runs that carry data and power together:
● Wireless access point drops
● PoE IP security cameras
● HD video and AV links
● Data center and telecom room links
● Enterprise LAN horizontal runs
● Respect the bend radius: The RDT cable has a 0.92 in minimum bend radius, which is four times its diameter. Keep every turn at or above that limit.
● Match your hardware: Terminate with Cat6A-rated jacks and patch panels. A lower-rated part limits the whole link to its own category.
Each cable comes in a 1000 ft length. Request a quote if your project needs several reels. To compare other brands, browse our Cat6a plenum Ethernet cable collection.