Belden CAT6A plenum cables carry 10 Gigabit Ethernet through the air-handling spaces of your building. The CMP jacket lets you run each cable above drop ceilings, below raised floors, and through return-air paths. Discounted Cables ships every order tax-free across the USA.
NEC Article 800 requires CMP-rated cable in plenum spaces. A Belden CAT6A plenum cable passes the UL 910 and NFPA 262 tests, which limit flame spread and smoke. Therefore, you can pull it through air-handling spaces and still meet code. Keep in mind that riser (CMR) cable is not allowed in these spaces, while CMP cable can replace it anywhere.
Every Belden CAT6A plenum Ethernet cable in this collection shares these specifications:
● 23 AWG solid bare copper conductors in four twisted pairs
● FEP insulation under a Flamarrest PVC-LS jacket
● 10GBASE-T performance across the full 100-meter (328 ft) channel
● IEEE 802.3bt PoE support, Types 1 through 4
● 1,000 ft lengths with a rip cord and descending footage markings
Belden CAT6 plenum cable carries 10 Gbps only up to about 55 meters, because crosstalk rises in dense bundles. A Belden CAT6A plenum Ethernet cable holds 10 Gbps across the full 100-meter channel. Therefore, choose CAT6A for longer runs and for future Wi-Fi 6 upgrades.
Choose unshielded (U/UTP) cable for most offices, schools, and hospitals. Choose shielded (F/UTP) cable near motors, elevators, and dense electrical runs. Terminate shielded cable with shielded jacks and a grounded patch panel.
Check the jacket print for "CMP" and a UL or ETL mark. CMR and CM cable cannot go in plenum spaces, so confirm the print before you pull.
Belden CAT6A plenum cable suits any indoor pathway that carries air. Common uses include:
● Runs above drop ceilings and below raised floors in offices, schools, and hospitals
● Return-air paths and other air-handling spaces
● Horizontal links to Wi-Fi 6 access points, IP cameras, and HDBaseT devices
● Data center and network backbone connections
Because the cable supports PoE Types 1 through 4, one run powers and connects each of those devices.
The Belden 10GXS13 holds a 25 lb maximum pull tension and a 2.75 in installation bend radius, so plan your pull and your corners ahead of time. Also, terminate every run with CAT6A-rated jacks and patch panels, because the weakest component sets the channel rating.
Compare other brands in our CAT6a plenum cable range, then add your Belden reels to the cart. Delivery is tax-free anywhere in the USA, and you can contact our team for project quantities.