The Wavenet Cat6A Riser cable (6A04URXX2) is a solid bare copper, 23 AWG unshielded twisted pair cable built for 10 Gigabit Ethernet over runs up to 1000 feet. It's rated to 750 MHz and verified to ANSI/TIA-568-C.2, so you're getting a cable that's been independently tested — not just claimed. The flame-retardant PVC jacket carries both CMR and FT4 fire ratings, which means it's code-compliant for vertical riser installations between floors. Inside, HDPE insulation keeps the signal clean, and a cross-web separator holds the four pairs in place to cut down on crosstalk. There's also a ripcord built in, which makes stripping the jacket during termination a lot less frustrating. It's RoHS compliant and C(ETL)US verified, and it comes on a 1000-foot spool — practical for large commercial or enterprise network builds where you're pulling a lot of cable at once.

Contact for Availability

$319.99 $349.99

Wavenet CAT6A Riser Ethernet Cable for 10G Networks

Wavenet CAT6A riser cables carry 10 Gigabit Ethernet through vertical shafts at a 750 MHz rating. Each spool holds 1,000 feet of 23 AWG solid bare copper, so you can pull long backbone runs from a single length. Discounted Cables stocks two versions: an Wavenet unshielded UTP cable and a Wavenet foil-shielded FTP cable.

Why Choose Wavenet CAT6A Riser

●       10G performance: Both cables support 10 Gigabit Ethernet across the full 750 MHz range. The UTP cable is verified to ANSI/TIA-568-C.2.

●       Full-distance speed: Cat6A holds 10 Gigabit speeds over 328 feet, while Cat6 reaches 10 Gigabit only up to 55 meters.

●       Solid bare copper: The 23 AWG conductors keep performance stable over long distances.

●       Riser-rated jacket: The flame-retardant PVC jacket on the UTP cable carries CMR and FT4 ratings for vertical runs between floors.

●       Verified safety: Both cables are ETL verified and RoHS compliant.

●       Stable pair geometry: A cross-web separator keeps the four pairs in position and protects the geometry that Cat6A performance requires.

Choose Between UTP and FTP

Wavenet 6A04URXX2 (UTP): This unshielded cable suits offices, schools, hospitals, and data centers. HDPE insulation keeps the signal clean, and the jacket carries a 75°C rating. A built-in ripcord lets you strip the jacket quickly. Six jacket colors (yellow, blue, red, green, white, and gray) help you label circuits.

Wavenet 6A04FRBL2 (FTP): In contrast, the foil shield protects signals in high-EMI areas such as factory floors, broadcast facilities, and server rooms near electrical panels. Wavenet documents its electrical performance from 1 MHz through 750 MHz, including attenuation, return loss, and NEXT. Ground the shield correctly at termination to get its full benefit.

Where to Use Wavenet CAT6A Riser Cable

Install your Wavenet CAT6A riser cable for backbone and horizontal runs in the riser shafts of office towers, university campuses, hospitals, and multi-floor commercial facilities. The solid copper conductors also support PoE devices such as access points and IP cameras.

Riser (CMR) cable suits vertical runs between floors. However, plenum (CMP) cable meets a stricter fire rating for plenum spaces, so use CMP there instead. Browse all Cat6a riser Ethernet cables to compare more options for your project.

Installation Tips

●       Terminate solid-core cable on punch-down blocks, patch panels, and keystone jacks. Use stranded patch cords for device connections.

●       Keep pull tension under 25 pounds-force and avoid sharp bends.

●       Test each link with a certifier after termination to confirm 10 Gigabit performance.

●       Confirm with your local authority having jurisdiction that CMR meets code for your shafts.